150GTL ALIGNMENT REVISION: 1.0 BURKE
Page:3 print date: 2/14/06
B. RX test equipment setup:
2.0
MAIN ALIGNMENT
2.1 PLL Alignment
STEP PRESET TO CONNECTIONS ADJUST PROCEDURE
1
RX mode, AM,
28.000MHz
Oscilloscope to TP1 T712
Check for range of 0.2 to
7VDC, then set to 2.8V
2 Change to Band D Oscilloscope to TP1 DC level should be < 6V
3 Same as step 1 Oscilloscope to TP2 T713 Adjust for maximum output
4 Same as step 1
Oscilloscope to 4th test
point of CON2
T717 Adjust for maximum output
5 Same as step 1
Frequency counter to
TP3
CT1
Adjust for 17.305MHz
(frequency – 10.695)
2.2 Carrier Alignment
STEP PRESET TO CONNECTIONS ADJUST PROCEDURE
1
TX mode, AM,
28.000MHz
Frequency counter to
TP3
CT2 Adjust for 28.000MHz
Noise Pulse
Generator
150GTL
Power
Supply
Generator
AC
VTVM
Oscilloscope
8 ohm Load