SPECIAL PROGRAMMING SECTION:
ARROW REVOLUTION
PIN CODE PROGRAMMING EASY MODE
PIN code programming in the Easy Mode requires the “I”
button to enter the programming mode. Adding or changing
codes deletes all existing PIN codes.
1. Unscrew battery cover hex screw using tool provided. Slide
battery cover up and off to reveal the “I” button located above
the batteries.
2. Press the “I” button once. Lock response: Register User code.
Enter 1 Supervisor then up to 8 users. Enter 4 to 12-digit PIN,
followed by “#” key. Press “I” button to complete.
3. Enter the new Supervisor PIN (4 to 12 digits) followed by the
“#” key.
Lock Response: Sounds a tone for each PIN digit with digits ashing
in the sequence entered to conrm the entry. Chime signals when
playback is complete.
4. Enter the first User PIN code (4 to 12 digits) followed by the
“#” key. Lock Response: Same as 3.
5. Enter additional User PIN codes (4 to 12 digits) followed by“#”
key. Up to 8 User PINs can be entered.
6. Press “I” button to complete the process after the last play-
back sequence. Lock Response: “Registered.
Notes: The “*” key is used to enter or accept an entry, and also
to conclude a programming session. The “#” key is used to enter
or to continue additional steps in a programming sequence.
RESET PROGRAMMING TO FACTORY DEFAULT:
Remove inside lever. Remove battery cover using Allen
wrench provided with lock. Remove batteries. Remove screw
from battery housing. Remove inside escutcheon.
On PC board, change position of EASY/ADVANCED
switch. This deletes all prior programming.
The Arrow
Revolution can
be programmed
in the Advanced
Mode having up to
1,000 Users. The
Advanced Mode
includes a Master
Code for program-
ming, not access.
This mode divides
Users into 20 Su-
pervisor Groups of
50 per group.
Categories Arrow Revolution
ANSI/BHMA A156.2 Grade 2
Cylindrical Lock Grade
UL/ULC fire rating UL - cUL Fire Label for
all functions up to 2 hours
Outside Lever Free Wheeling
Notes: Outside lever disengages
when locked
Cylindrical or mortise? Cylindrical, mortise
Lever Handing Non-Handed
Field reversible? Yes
Key Override Yes
Optional Yes
Keypad Layout 12-Button telephone style
Button Type Touch screen
Code Hierarchy Easy Mode (Nine Users),
Supervisor, Users
Master Code Supervisor PIN
Number Of Digits Four to 12
Factory Default 1-2-3-4-5-6-7-8-9-0
Master Code Supervisor PIN
Notes: Factory default setting is
Easy Mode. Arrow uses PIN
instead of code
Sub-master Codes Not in Easy Mode
User Codes no. up to 8
number of digits Four to 12 digits
Note: When adding
or changing PINS, all
existing PINs are deleted
and must be re-entered.
Single use (service code) n/a
Successful Entry When correct code and “*”
or palm touch is entered,
the illuminated display roles
upward, like a window blind
opening.
User code groups n/a
Levels of access Code Required, Passage,
Lockout
Lock-out/down Advanced mode only
Programming Capabilities:
Codes on hold n/a
Anti-Tamper Five unsuccessful attempts at
entering a valid PIN code the
unit will shut down and not
allow operation.
Weatherized model Weather resistant
Battery Life Approximately 20,000
operations
Low Batteries Warning n/a
Batteries Four AA Alkaline Batteries
Battery Location Inside back cover
Battery Replacement 3/32” hex wrench
Information Warnings 9 Volt battery connections
under front of exterior
escutcheon for emergency
power
48 — LOCKSMITH LEDGER [11/10] www.locksmithledger.com